Trimmer Description
TC
Setting automatic closing time. From 0 to 30 s.
Note: after the activation of the stop command, once contact 1-9 has closed again, the
automatic closing is only activated after a total, partial or step-by-step opening command.
RP Motor partial opening adjustment. From 0 to 30 s.
Jumpers Description OFF ON
SO
Reversal safety switch
function.
With the automation blocked, if the
contacts 41-8 are open, it is possible to
activate the opening operation.
With the automation blocked, if
the contacts 41-8 are open, any
operation is impossible.
EO Electric brake.
Do not use Normal.
0 s 30 s
0 s 30 s
SIGNALS AND SETTING
Button LED
Starts the opening operation. The green LED on indicates the presence of the 24 V=power supply.
Starts the partial opening operation.
Starts and stops the STOP operation.
the red LED on indicates that the STOP has been activated.
the ashing red LED indicates that the safety devices have been activated.
Starts the closing operation.
ON
 Description OFF ON
DIP 1  Step-by-Step Opening
DIP 2
Restore automatic closing
time.
Do not use 100 %
DIP 3 
Disabled during
opening
Enabled for both
opening and closing
DIP 4 Application type. Do not use Rapid door
DIP 5 Dynamic brake. Disabled Do not use
DIP 6 Double speed Disabled Do not use
LED On Flashing
POWER 24 V= power supply. /
SA
Indicates that at least one of the safety
contacts is open. ( 6 - 8 - 9 )
- Indicates the STOP operation activated by pushbutton panel
PT4 (if present).
- If the AUTOTEST device is installed, this indicates a safety
test failure (terminal 41).
- On power on, the LED ashes to indicate the number of
operations performed:
each rapid ash = 10000 operations
each slow ash = 100000 operations
IN
Activated at every command and
adjustment to the dip-switch and jumper.
/
11
Indicates that the 0-11 limit switch
contact is open.
/
12
Indicates that the 0-12 limit switch
contact is open.
/
17
Indicates that the 0-17 limit switch
contact is open. (not used)
/
1 2 3 4 5 6
ON


setting