5.1 Installation
5. Chain link-up installation
- After having determined the position of the wall bracket, drill the holes and secure the bracket in place with dowels (not included)
1
.
- Fit the crown wheel onto the sectional door shaft and insert the appropriate cotter depending on shaft cavity length
2
. Fasten the
metal clamp
3
so as to prevent the risk of the cotter coming out of the shaft.
- Link up crown and pinion by means of the chain. Properly tauten the chain by acting on the wall anchoring brackets. Fix the bracket
A
to avoid that the shaft of the sectional bends and to guarantee the correct tensioning of the chain.
ATTENTION! firmly tighten down all fastening screws.