Installation Instructions
27
IP2246EN
Display Description
Selections
available
OC - Obstacle detection limit during closure [%]
Indicates the percentage of the distance travelled during
→ or after the detection of the closing limit switch
→ → on which the reversal is deactivated.
NB: not active if
→ → and if → → .
99
TO - Setting motor 2 opening delay time [s]
Adjustment, in seconds, of the delay time for starting
the operation of motor 2, in relation to motor 1.
03
LR - Electric lock release time [s]
If enabled, this indicates the electric lock activation time at the start
of every opening operation with the automation closed.
1.5
M1 - Operation time - motor 1 [s]
Adjustment, in seconds, of the total operation time for motor 1.
i
WARNING: it is set with a sensitivity interval of 0.5 s, shown
when the decimal point on the right lights up.
Example:
= 7 seconds / = 7.5 seconds
NB: the setting of is only active with → → .
10
M2 - Operation time - motor 2 [s]
Adjustment, in seconds, of the total operation time for motor 1.
i
WARNING: it is set with a sensitivity interval of 0.5 s, shown
when the decimal point on the right lights up.
Example:
= 7 seconds / = 7.5 seconds
NB: the setting of is only active with → → .
10
EO - Function of output -LK+
00 - courtesy light
01 - electric lock
02 - electric lock + release stroke
03 - output active with automation closed (for electromagnets of the fail-safe type)
04 - output active with automation open
05 - output active with automation moving (can also be used for electromagnets that need
to be powered throughout the operation)
06 - output active with automation opening
07 - output active with automation closing
08 - output active with maintenance alarm triggered
09 - output active for indicating batteries almost flat
10 - ON-OFF flashing light for LED without oscillator
11 - ON-OFF flashing light
ON - output always active
FF - Function of output +LP-
00 - courtesy light
01 - ON-OFF flashing light
02 - fixed light with internal oscillator
03 - output active with automation closed
04 - output active with automation open
05 - output active with automation moving
06 - output active with automation opening
07 - output active with automation closing
08 - output active with maintenance alarm triggered
09 - output active for indicating batteries almost flat
10 - ON-OFF flashing light for LED without oscillator
11 - electric lock
12 - electric lock + release stroke
ON - output always active
BA