9. Outputs and accessories
Output
Value of
accessories
Description
0
-
1
+
24V / 0.5 A
Power supply to accessories
Output for power supply to external accessories.
NB: the maximum absorption of 0.3A corresponds to the sum
of all terminals 1.
The "gate open" indicator light (30-13) is not calculated in the
0.3A indicated above. The maximum value to be considered
is 3W.
GOL148REA
If the GOL868R4 radio receiver is used (868.35 MHz), connect the
supplied antenna wire (90mm).
+LP-
LAMPH
24V / 25W
Flashing light
The pre-flashing settings can be selected from the third level
menu
→ and/or → .
To modify the operating mode of the LP output, refer to the
selection
→ .
30 2 3 4 9 13
24V / 3W
Automation status lamp
For the operating mode of output 30-13, refer to the selection
→ .
-+LK
12V~ / 15W
Electric lock
It is activated when the operation begins with the automation
closed.
To modify the operating mode of the LK output, refer to the
selection
→ .
AUX 1
AUX 2
SOFA1-SOFA2
GOPAVRS
LAN4S
LAB9
BIXLR12
BIXLR22
GOL868R4
BIXLR42
LAN7S
The control panel has two slots for plug-in command and
safety boards.
The action of the control board can be selected using
→
for AUX1 and → for AUX2.
When using slot-in radio boards, remove the RDX module.
The display will show
.
WARNING: the plug-in board must be inserted and removed
with the power supply disconnected.
RDX
6ZENRS
ZENPRS
The control panel is fitted with a housing for modules of the
6ZENRS radio receiver type (433.92 MHz).
Can be replaced with a radio receiver module of the ZENPRS
type (868.35 MHz).
The operating mode is selected via
→ .
When using slot-in radio boards, remove the RDX module.
The display will show
.
WARNING: the modules must be inserted and removed with the