20. START-UP
WARNING The operations related to point 5 are performed without safeties.
The trimmer can only be adjusted with the automation idle.
The automation automatically slows when approaching the end stops.
At every start-up the control panel receives a RESET and the rst operation is performed
at reduced speed (automation position acquisition).
1- Make a jumper for the N.C. safety contacts.
2- Set TC=MAX and R1=MAX.
3- Use DIP2 to set the required direction.
4- Manually move the door and make sure the entire stroke is correct and without friction.
5- Switch on and check that the automation is operating correctly with subsequent opening and closing
commands.
6- Connect the safety devices (removing the relative jumpers) and check they work correctly.
7- If required, activate automatic closing and adjust the time with the TC trimmer.
8- Set the obstacle thrust with the R1 trimmer.
WARNING: check that the working forces exerted by the door wings are compliant with EN12453-EN12445
regulations.
9- Connect any other accessories and check they operate correctly.
i
NOTE: in the event of servicing or if the control panel is to be replaced, repeat the start-up procedure.