- The SIC852 photocell must be installed upon the perimeter
pro¿le or else upon the ¿[ed wing as shown in the diagram
and in the PAM4 ASMI manual.
-
Perform the electrical connections as shown in the diagram.
$ttention: ,f the &20+. function seOector is used, connect
the receiYer¶s Erown caEOe to terminaO on the seOector
- An\ other arrest devices must be connected in series to
terminal (STOP).
- :hen the receiver (5;) and the transmitter (T;) of the
photocell SIC852 are powered and correctl\ aligned the
green /ED on the transmitter T; and the \ellow /ED on the
receiver 5; will light up. The \ellow /ED on the receiver will
go out when the\ are no longer correctl\ aligned.0
- Once installation has been completed checN to maNe sure
that the force required to open each single wing does not
e[ceed 220 N.
This reading must be taNen at 1 m from Àoor level in corre-
spondence to the closure side of the wing (opposite to the
hinges). The breaNawa\ force can be adjusted as indicated
in paragraph .18.
- ChecN that the door¶s automatic movement stops when the
mobile wings are released. The SIC852 photocell serves
the purpose of detecting the release of the mobile wings.
7. ASMI ELECTRICAL CONNECTIONS