Instruction Manual
- 27 -
0DT866 10-05-2022
MESSAGE SITUATION NOTES
Ditec door closed waiting for command
Opening of VBUS IBUS door opening
Door open - automatic closing time Door open
Closing of VBUS IBUS door closing
Input 40 closed; input 8 open intervention of photocell When door is moving
input 40 open; input 8 closed Primary safety device intervention
(SLEC / SAFETY EDGE)
When door is moving
Limit switches open Intervention of safety microswitch on manual
opening device / intervention of thermal
protection on motor / opening (A) and closure
(C) limit switches simultaneously active.
Opening safety device activated photocell engaged when door is closed
and door does not open
Message that only appears if the "safety
in open" function is set to YES on the
advanced menu (step 7).
Door stopped stop command activated
Stand by encoder New control panel power on / replacing
control panel power on
Absolute Encoder not connected.
Control panel already programmed to
work with motor having absolute encoder.
To reset see troubleshooting chapter.
7. ALARMS
8. INTERLOCK
6.4 Service menu (password required)
To access the Service menu:
- STOP the door
- Set DIP5 to ON
- Enter the PW: button sequence OPEN- OPEN- CLOSE- PARTIAL OPENING
1 2 3 4 5 6 7 8
ON
ONCE PROGRAMMING HAS ENDED, SET DIP5 TO OFF
STEP 1
st
level options Notes
1 MIN BRAKING VOLT. Default 340Vdc Threshold for partial intervention of braking resistance
2 MAX BRAKING VOLT. Default 380Vdc Threshold for total intervention of braking resistance
3 OVERCURRENT LIMIT
Default 10A
If the current on the BUS exceeds the set threshold, the door opens at
half the speed to reduce absorption.
4 RAMP SLOPE DURING OPENING Changes the slope of the deceleration ramp when opening. Default 15.
(If the value is increased, the ramp distance is reduced).
5 BATTERY LEVEL Visualizes the encoder battery charge level from 0% to 100%
6 ALARM LIST The last 50 alarms are displayed: Overcurrent; bus voltage exceeds limit,
Intervention of brake resistance, inverter overtemperature, faulty motor
driver (encoder). To exit, press partial opening
Remove cables from PIN 3, 4, 20 during programming
+24V
INPUT
1 IN NC C NO
QE 52E
QE 52E
+24V
INPUT
1 IN NC C NO
M4 M4
Logical
operation
DOOR 1 DOOR 2
EN