Instruction Manual

- 26 -
0DT866 10-05-2022
ONCE PROGRAMMING HAS ENDED, SET DIP2 TO OFF
STEP 1
st
level options Scrolling Conrm 2
nd
level options Notes
1 CYCLIC MODE
TIMER OFF
Timer not active
TIMER ON Timer active
2 TIME UNIT
MIN.
Timer by minuts
SEC. Timer by seconds
3 OPENING TIME
1 …200
Set the regular time intervals
4 AUTO CLOS.TIME
1….200
Set the time during which the door
remains open
5 TOT
VALUE
Cycle counter
6 RESET CYCLES
RESET?
Cycle counter reset
6.3 Timed opening menu
With door in STOP position and DIP 8 ON you enter the menu CYCLIC MODE. By activating this mode it is possible to set
a timed opening at regular time intervals. Once the mode is set put DIP 8 OFF.
When CYCLIC MODE is active, the display shows every 2 sec:
TOT cycle - count down to next open/OPENING TIME
STEP 1
st
level options Scrolling Conrm 2
nd
level options Notes
12 Closing speed
in (Hz)
CHANGE VALUE
The setting of higher values
must be assessed according to
door dimensions and operating
conditions.
13 Service Alarm
YES
NO
RESET? Restart the service count down
14 Service thresh
CHANGE VALUE
Option available only if YES has
been selected for point 13).
Set value to steps of 1000 cycles
Max 200,000 cycles
15 Enable stop 1-2
YES
If set to YES, opening of the
contact 1-2 STOPS the door.
NO
16 Brake resistance
(default NO)
YES
Set to YES when the door is
supplied with brake resistance.
NO
17 PARAMETER RESET
CONFIRM
Conrm to go back to the
installation menu.