Instruction Manual
- 24 -
0DT866 10-05-2022
6. PROGRAMMING
STEP 1
st
level options 2
nd
level options Menu scrolling Notes
1
Select language
Conrm with:
Conrm with:
ENGLISH
ITALIAN
FRANÇAIS
DEUTCH
ESPANOL - POLSKA
CESKY - MAGYAR
2
Door model
Conrm with:
Conrm with:
SOFT RESET
SECTOR RESET
SMART PLUS
SECTOR PLUS
TRAFFIC C
SMART RESET
3
Position control
Conrm the Limit Switch option
with:
Conrm with:
LIMIT SWITCH
ENCODER
4
Calibrating positions
The door will move to the required
position in operator present mode and
at low speed.
Conrm the Limit Switch position after
setting
Conrm with:
CLOSED POSITION
PARTIAL POSITION
(indicates the deceleration start
position)
OPEN POSITION
5
Command mode
Conrm with:
Selecting 1-9: if 1-9 is closed, the
command mode will be impulsive, if
1-9 is open the command mode will be
“dead man”
Conrm with:
IMPULSIVE
MAN PRESENT
INPUT 1-9
6
CONFIRM DATA
Conrm with:
6.1 INSTALLATION MENU
When the control panel is switched on, after showing the messages DITEC and microprocessor and card FW VERSION,
the device automatically enters the installation menu and displays the message SELECT LANGUAGE.
PROGRAMMING COMPLETED
The door is now programmed and operating with the set default speed values.
With the door MOVING, the voltage and current values will be displayed on the BUS.
Conrm with
Remove cables from PIN 3, 4, 20 during programming










