6 PROGRAMMING MENU
6.1 INSTALLATION MENU
When the control panel is switched on, after showing the messages DITEC and microprocessor and card FW VERSION,
the device automatically enters the installation menu and displays the message SELECT LANGUAGE.
Conrm with
Remove cables from PIN 3, 4, 20 during programming
STEP 1
st
level options 2
nd
level options Menu scrolling Notes
1
Select language
Conrm with:
Conrm with:
ENGLISH
ITALIAN
FRANÇAIS
DEUTCH
ESPANOL - POLSKA
CESKY - MAGYAR
2
Door model
Conrm with:
Conrm with:
SOFT RESET
SECTOR RESET
SMART PLUS
SECTOR PLUS
TRAFFIC C
SMART RESET
3
Position control
Conrm with:
Conrm with:
ENCODER
LIMIT SWITCH
4
Calibrating positions
The door will move to the desired
position in man present mode and at
low speed.
Conrm position with:
Conrm with:
CLOSED POSITION
PARTIAL OPEN POS.
OPEN POSITION
5
Command mode
Conrm with:
Selecting 1-9: if 1-9 is closed, the
command mode will be impulsive, if
1-9 is open the command mode will be
“dead man”
Conrm with:
IMPULSIVE
MAN PRESENT
INPUT 1-9
6
CONFIRM DATA
Conrm with:
PROGRAMMING COMPLETED
The door is now programmed and operating with the set default speed values.