User Manual
- 31 -
0DT829 01-12-2021
Ref. Description
1 Box
2 Gear motor K10
3 Winding shaft
4 Transmission chain
5 Counterweight belt drum
6 Manual release lever
7 Safety edge aluminium prole
8 Safety edge rubber prole
9 Safety edge connection box
10 Safety edge connection cable
11 Counterweight belt
12 Modular counterweight
13 Right-hand column cover
Ref. Description
14 Left-hand column cover
15 Right-hand column
16 Left-hand column
17 Curtain aluminium proles
18 Curtain reinforcing tube
19 Control panel
20 Photocell LAB4
21 Curtain lifting belt
22 Curtain belt attachment
23 Transparent section
24 Polyester section
25 Safety edge protective pocket
2. TECHNICAL CHARACTERISTICS
CONTROL PANEL TRIPHASE (49E)
Power supply voltage ............400 V triphase 50/60 Hz
Line sizing ............................................................... 6 A
Auxiliary control power voltage ........................24V
Motor rating ..........................................0,55 ÷ 1,8 KW
Control board protection class ............................ IP 55
Operating temperature .............................. - 5 + 50 °C
CONTROL PANEL INVERTER (52E)
Power supply voltage ........ 230 V monofase 50/60 Hz
Line sizing ............................................................. 16 A
Auxiliary control power voltage ........................24V
Motor rating ..........................................0,55 ÷ 1,8 KW
Control board protection class ............................ IP 55
Operating temperature .............................. - 5 + 50 °C
Correctly size the line conductor cross-section by referring to the indicated absorption and taking the length and
installation of the cables into account.
15
20
13
21
34
5
12
7
8
14
18
9
16
10
25
24
23
22
12
11
6
17
19
EN