Owner's manual
SK750/SK755 Operator’s Manual Transport - 47
Tow
CMW
®
Tow
Under normal conditions, unit should not be towed. If unit breaks down and towing is necessary:
• attach chains to tow points facing towing vehicle
• tow for short distances at less than 1 mph (1.6 km/h)
• do not tow for more than 100’ (30 m)
• use no more than 1,300 lb (5800 N) of towing force
• open bypass valve on each pump section
• disengage parking brake
Read operator’s manual. Know how to use all controls
before operating machine. When you see this sign on the machine or
in the manual, read it and use caution. Your safety is at stake.
NOTICE: When bypass valve is open, unit has no brakes.
t35om007w.eps
t35om006w.eps
front tow point
rear tow point