Owner's manual

SK750/SK755 Operators Manual Transport - 47
Tow
CMW
®
Tow
Under normal conditions, unit should not be towed. If unit breaks down and towing is necessary:
attach chains to tow points facing towing vehicle
tow for short distances at less than 1 mph (1.6 km/h)
do not tow for more than 100’ (30 m)
use no more than 1,300 lb (5800 N) of towing force
open bypass valve on each pump section
disengage parking brake
Read operator’s manual. Know how to use all controls
before operating machine. When you see this sign on the machine or
in the manual, read it and use caution. Your safety is at stake.
NOTICE: When bypass valve is open, unit has no brakes.
t35om007w.eps
t35om006w.eps
front tow point
rear tow point