User Manual

MV800 Operator’s Manual Service - 83
As Needed
CMW
®
As Needed
Vacuum System
Change Water Pump Filter
1. Open filter housing.
2. Remove element and rinse housing
thoroughly with clean water.
3. Install new element and close filter housing.
Lube Blower for Long-term Storage
Lubricate blower before long-term storage to help
prevent rust and seizing.
1. Remove filter.
2. Start engine.
3. Spray light oil into port and run unit for 1-2
minutes.
4. Turn off engine.
Location Task Notes
VACUUM
SYSTEM
Change water pump filter
Lube blower for longterm storage
Change blower relief air filter
Check battery
DEBRIS
TANK
Clean primary shutoff valve