Manual

JT100/JT100 All Terrain Operator’s Manual Controls - 49
Right Control Console
CMW
©
Most engine display functions are self-explanatory. For more information about functions, see the
manufacturer’s instructions at www.fwmurphy.com.
Main Menu
4. Engine coolant
temperature gauge
Displays engine coolant
temperature.
Normal coolant temperature is 180°-
230° F (82°-110° C).
5. Engine oil pressure
gauge
Displays engine oil pressure. Full load reading should be 60-80 psi
(4.1-5.5 bar).
6. DPF regen mode key Toggles between automatic
(ECU-controlled) and
inhibited DPF regeneration
modes.
Inhibited mode allows the operator to
delay regeneration. The system will
continue to alert the operator that
regeneration is required until the
regeneration is started.
7. Soft key Press to select a soft key
command.
Soft key commands change with each
menu screen and are displayed next
to the key.
8. Main menu key Press from main screen
(gauges) to select main
menu.
9. Soft key Press to select a soft key
command.
Soft key commands change with each
menu screen and are displayed next
to the key.
10. Day/Night mode key Press from main screen
(gauges) to toggle between
day and night modes.
11. Voltmeter display Shows system voltage. Normal voltage is 13-14V with engine
running.
12. Fuel gauge Displays amount of fuel
remaining in tank.
See “Approved Fuel” on page 189.
IMPORTANT: Soft key commands change with each menu screen and are displayed next to the key.
Item Description Notes
10. System settings key Press to select system
settings menu.
System settings menu displays
information about the system.
Diagnostic information is only
available to dealer technicians.
9. User settings key Press to select user settings
menu.
User settings menu allows user to
change the language and unit
settings, and to set the time and date.
Item Description Notes