Manual
Service - 216 JT100/JT100 All Terrain Operator’s Manual
2000 Hour
CMW
©
Change Rotation, Thrust, and Fluid
Pump Remote Charge Filter
Change remote charge filter every 1000 hours,
when changing hydraulic fluid, or when indicated
by visual indicator (shown).
2000 Hour
Drilling Unit
Change JT Fluid Pump Oil
Drain oil at plug (3). Add 12 qt (11.3 L) of NDO at
fill (1) until oil level is at middle of sight tube (2).
Location Task Notes
DRILLING
UNIT
Change JT fluid pump oil NDO
Change engine coolant DEAC
Check seatbelt and seatbelt mounting hardware
LOADER/
DRIVER
Change anchor driver gearbox oil MPL