Manual
Systems and Equipment - 176 JT100/JT100 All Terrain Operator’s Manual
Diagnostic Codes
CMW
©
144 charge air cooler sensor error fan may turn fully on and code is
stored
non-
essential
151 drill joystick left/right out of range rotation, cruise control and drive are
blocked and code is stored
essential
152 drill joystick forward/backward out of
range
thrust, cruise control and drive are
blocked and code is stored
essential
153 no continuity to inner rotation jog pot code is stored non-
essential
154 drilling fluid potentiometer out of
range
code is stored essential
155 rotation potentiometer is out of range code is stored non-
essential
215 no continuity to float position sensor assisted makeup is blocked and code
is stored
non-
essential
221 system voltage is below 9V code is stored non-
essential
222 inner rotation position sensor not
changing
dither compensation is blocked non-
essential
233 drill and drive inputs both on drill and drive are blocked and code is
stored
essential
234 add pipe and remove pipe inputs both
on
add pipe and remove pipe are
aborted, blocked and code is stored
non-
essential
235 front home and rear home inputs both
on
add pipe and remove pipe are
aborted, blocked and code is stored
non-
essential
241 shuttles not responding correctly add pipe or remove pipe is aborted,
blocked and code is stored
non-
essential
244 rotation not responding correctly auto carve mode is replaced with
manual carve
non-
essential
245 FRAM parameter table length change code is stored non-
essential
254 error reading setup table information add pipe and remove pipe are
aborted, blocked and code is stored
essential
255 undefinable diagnostic code reported code is stored non-
essential
Code Condition Result Severity