Manual

Vacuum and Pothole - 66 FX60/FXT60 Tier 4 Operators Manual
Connect Hoses
CMW
®
Connect Hoses
1. Remove vacuum hoses from storage.
If using 1200:
Disconnect hose end from hose catch.
Insert hose through rollers (2).
Pull vacuum hose reel control (1) down to
unwind hose.
Disconnect hose end (3) from hose reel.
2. If potholing, remove 2-in-1 potholing tool or basic
potholing tool from storage.
3. Connect hoses. Secure all locking clamps.
4. Ensure drain/outlet valve is closed.
5. If potholing, connect water pressure hose.
2-in-1 Tool Basic Tool