Owner manual
Service - 96 FX50 Operator’s Manual
250 Hour
CMW
Debris Tank
Check Tank Mounting Bolts
Check vacuum tank mounting bolts (shown, on
both sides) every 100 hours for looseness and
damage. Tighten or replace as needed.
Vacuum Boom
Check Structure
Check boom elbow every 100 hours. Replace as needed.
250 Hour
Vacuum System
Inspect Air Intake System
Inspect intake piping for cracked hoses, loose
clamps, or punctures. Tighten or replace parts as
necessary.
Location Task Notes
Vacuum
System
Inspect air intake system
j36om038w.eps