Manual
FX30/FXT30 Operator’s Manual Controls - 29
Power Pack
CMW
®
2. Water pressure switch To turn on water pump, press
top.
To turn off water pump, move
to center position.
To bypass low water
indication, press bottom.
Water pump will operate for
60 seconds.
Use bypass to feed antifreeze into
system when freshwater tank is
empty. See “Add Antifreeze” on
page 76.
3. Tethered tank control
outlet (FX30 only)
Connection for tethered tank
lift/lower control.
IMPORTANT: The outlet for FXT30
units is at the back of the unit.
4. Water pressure control To increase water pressure,
turn clockwise.
To decrease water pressure,
turn counterclockwise.
5. Ignition switch To start engine, insert key and
turn clockwise.
To stop engine, turn key
counterclockwise.
NOTICE: Do not start unit unless flow
direction control is in vacuum mode.
IMPORTANT:
• When engine is on, blower
operates and vacuum is present
at tank inlet.
• All indicators should light briefly at
startup.
6. Auxiliary outlet switch To turn on, press top.
To turn off, press bottom.
Item Description Notes
c00ic601h.eps
H
c00ic060t.eps
H
c00ic061t.eps