Manual

FX30/FXT30 Operator’s Manual Service - 111
As Needed
CMW
®
Debris Tank
Clean Primary Shut-off Valve
Clean primary shut-off valve as needed. Replace
primary shut-off valve as needed.
To clean:
1. Open tank door. See “Open/Close Tank Door”
on page 73.
2. Spray valve housing inside vacuum tank with
high-pressure water.
3. Store water pressure hose.
4. Close tank door. See “Open/Close Tank Door”
on page 73.
To remove:
1. Loosen three wingnuts (1) and pull out valve housing (2).
2. Remove ball (3).
3. Clean ball and housing with high-pressure water.
4. Replace ball and housing.
5. Tighten wingnuts.
22
33
11
j33om049h.epsj33om049h.eps