Manual
FX30/FXT30 Operator’s Manual Service - 101
100 Hour
CMW
®
100 Hour
Vacuum System
Change Fuel Filters
Replace filters (1, 2) every 100 hours.
1. Remove filter.
2. Install new filter. Apply fuel oil thinly over the
gasket and hand-tighten.
3. Bleed air from the injection pump. (See engine
manufacturer’s manual for instructions.)
Change Blower Oil
Change oil after the first 100 hours of operation,
and every 1000 hours thereafter. Change oil more
frequently if working in dusty conditions.
• Drain at drain plug (4) while oil is warm.
• Add with SGL at fill (2) until oil is at halfway
point on sight glass (3).
Location Task Notes
VACUUM
SYSTEM
Change fuel filters
Change blower oil initial service, SGL
Change hydraulic fluid initial service, THF
Change water pump oil NDO
DEBRIS
TANK
Check tank mounting bolts
VACUUM
BOOM
Check structure Boom is optional equipment
Check boom deflector and plate seal
2
3
4
j33om041h.epsj33om041h.eps