User guide

FX25 Operator’s Manual Service - 91
As Needed
CMW
Debris Tank
Clean Primary Shut-off Valve
Clean primary shut-off valve as needed. Replace
primary shut-off valve as needed.
To clean:
1. Open tank door. See “Drain Tank” on page 51.
2. Spray valve housing inside vacuum tank with
high-pressure water.
3. Store water pressure hose.
4. Close tank door. See “Drain Tank” on
page 51.
To remove:
1. Loosen three wingnuts (1) and pull out valve housing (2).
2. Remove ball (3).
3. Clean ball and housing with high-pressure water.
4. Replace ball and housing.
5. Tighten wingnuts.
2
2
3
3
1
1
j32om026h.eps