Service - 116 410sx Operator’s Manual
As Needed
Check Batteries
Check batteries as needed. Keep batteries clean
and terminals free of corrosion.
To clean:
1. Turn battery disconnect switch, if equipped, to
the off position.
2. Ensure that no ignition sources are near
batteries.
3. Loosen and remove battery cable clamps
carefully, negative (-) cable first.
4. Clean cable clamps and terminals to remove
dull glaze.
5. Check for signs of internal corrosion in cables. Replace battery and/or cables if damaged.
6. Apply MPG to terminals after cleaning to reduce corrosion.
7. Connect battery cable clamps, positive (+) cable first.
8. Tighten any loose connections.
9. Ensure that battery tiedowns are secure.
10. Turn battery disconnect switch to the on position.
NOTICE: For the 410sx Gas, ONLY USE the following replacement battery: Optima 8004-003
(p/n 215-1165).
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.
To help avoid injury:
• Do not create sparks and do not short across battery terminals for any reason.
• Do not operate 410sx Gas unit without battery heat shields in place.
t39om074w.eps