4. Absolute Maximum Ratings
Parameter
Symbol
Min
Max
Unit
Notes
Supply Voltage for Operation VCI -0.3 4 V 1, 2
Supply Voltage for Logic VDD -0.5 2.75 V 1, 2
Supply Voltage for Display VCC -0.5 19 V 1, 2
Operating Temperature TOP -40 +80 °C -
Storage Temperature TSTG -40 +80 °C -
Note 1: All the above voltages are on the basis of “VSS = 0V”.
Note 2: When this module is used beyond the above absolute maximum ratings, permanent
breakage of the module may occur. Also, for normal operations, it is desirable to use this
module under the conditions according to Section6 “Electrical Characteristics”. If this module is
used beyond these conditions, malfunctioning of the module can occur and the reliability of the
module may deteriorate