4. Absolute Maximum Ratings 
Parameter  Symbol  Min  Max  Unit  Notes 
Supply Voltage for Logic  VDD  -0.3  4  V  1, 2 
Supply Voltage for Display  VCC  0  15  V  1, 2 
Operating Temperature  TOP  -40  +80  °C  - 
Storage Temperature  TSTG  -40  +80  °C  - 
Note 1: All the above voltages are on the basis of “VSS = 0V”. 
Note 2: When this module is used beyond the above absolute maximum ratings, permanent 
breakage of the module may occur. Also, for normal operations, it is desirable to use 
this module under the conditions according to Section 6 ‘’Electrical Characteristics’’. 
If this module is used beyond these conditions, malfunctioning of the module can 
occur and the reliability of the module may deteriorate 