Datasheet

DEM 640480D TMH-PW-N (C1-TOUCH) Production Specification
Version: 0 PAGE: 20
9. Incoming Inspection Standards
9.1 Inspection and Environment Conditions
9.1.1 Inspection Conditions:
(1)Inspection Distance: 35 c5cm
(2)View Angle : Light-on Inspection Angle±5° Cosmetic Inspection Angle±45°
Light
-
on
Insp.
Cosmetic
Insp.
45
°
5
°
30cm~40cm
90
°
TFT
-
LCD
( perpendicular to LCD panel surface)
9.1.2 Environment Conditions:
Ambient Temperature
23
±5
Ambient
Humidity
55±10%RH
Ambient
Illumination
Cosmetic Inspection more than 600 Lux
Functional
Inspection
300~500 Lux
9.1.3 Sampling Conditions:
(1)Lot Size: Quantity of shipment lot per model
(2)Sampling Method:
Sampling Plan
MIL
-
STD
-
105E
Normal
Inspection,
Single Sampling
Level
II
AQL
Major
Defect
1.0%
Minor
Defect
1.5%
(3)The classification of Major(MA) and Minor(MI) defects is shown as 3. Inspection Criteria.