7. Reliability Condition
No change on display and in operation under the following test condition.
Condition: Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20±5°C Humidity: 65±5%RH
Tests will be not conducted under functioning state.
No. Parameter Condition Notes
1 High Temperature
Operating
70°C±2°C, 240hrs (Operation state)
-
2 Low Temperature Operating
-20°C±2°C, 240hrs (Operation state) -
3 High Temperature Storage 80°C±2°C, 240hrs -
4 Low Temperature Storage -30°C±2°C, 240hrs -
5 High Temperature and High
Humidity Operation Test
60°C±2°C, 90%, 240hrs. -
6 Vibration Test Total fixed amplitude: 1.5mm
Vibration Frequency: 10~55Hz
One cycle 60 seconds to 3 direction of X, Y, Z
each 15 minutes.
-
7. Drop Test To be measured after dropping from 60cm high
on the concrete surface in packing state.
-
Notes: 1. No dew condensation to be observed.
2. The function test shall be conducted after 4 hours storage at the normal
temperature and humidity after removed from the test chamber.
3. Vibration test will be conducted to the product itself without putting I in a container.
Dropping method corner
dropping
A corner: once
Edge dropping
B, C, D edge: once
Face dropping
E, F, G face: once
A
B
E
G
D
C
F
60cm
Concrete Surface