Datasheet
DEM 320240R TMX-PW-N Production Specification
Version: 0 PAGE: 19
12 Incoming Inspection Standards
12.1 Inspection and Environment Conditions
12.1.1 Inspection Conditions:
(1)Inspection Distance: 35 cm±5cm
(2)View Angle : Light-on Inspection Angle︰±5°
Cosmetic Inspection Angle︰±45°
( perpendicular to LCD panel surface)
12.1.2 Environment Conditions:
Ambient Temperature
23℃±5℃
Ambient Humidity 55±10%RH
Ambient
Illumination
Cosmetic Inspection more than 600 Lux
Functional Inspection 300~500 Lux
12.1.3 Sampling Conditions:
(1) Lot Size: Quantity of shipment lot per model
(2) Sampling Method:
Sampling Plan
MIL-STD-105E
Normal Inspection, Single Sampling
Level II
AQL
Major Defect 1.0%
Minor Defect 1.5%
(3) The classification of Major(MA) and Minor(MI) defects is shown as 3. Inspection Criteria.
TFT-LCD
45
Cosmetic Insp.
Light-on Insp.
5
30cm~40cm
90










