Datasheet

DEM 320240R TMX-PW-N Production Specification
Version: 0 PAGE: 17
10 Reliability Condition for LCD
No change on display and in operation under the following test condition.
Condition: Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20°C±5°C Humidity: 65°C±5%RH
Tests will be not conducted under functioning state.
No. Parameter Condition Notes
1 High Temperature Operating +85°C±2°C, 240hrs (Operation state) --
2 Low Temperature Operating -30°C±2°C, 240hrs (Operation state) --
3 High Temperature Storage +85°C±2°C, 240hrs --
4 Low Temperature Storage -30°C±2°C, 240hrs --
5 High Temperature and High
Humidity Operation Test
+60°C±2°C, 90%, 240hrs
--
6 Vibration Test Total fixed amplitude: 1.5mm
Vibration Frequency: 10~55Hz
One cycle 60 seconds to 3 direction of X, Y, Z each
15 minutes.
--
7
Thermal Shock Test
(non-operating)
-30°C30min~ +85°C30min,10 cycles
8 Drop Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
--
Notes: 1. No dew condensation to be observed.
2. The function test shall be conducted after 4 hours storage at the normal temperature and
humidity after removed from the test chamber.
3. Vibration test will be conducted to the product itself without putting I in a container.
Dropping method corner
dropping
A corner: once
Edge dropping
B, C, D edge: once
Face dropping
E, F, G face: once
A
B
E
G
D
C
F
60cm
Concrete Surface