Datasheet
DEM 320240I TMH-PW-N (A-TOUCH) Production Specification
Version: 0 PAGE: 20
9. Incoming Inspection Standards
9.1 Inspection and Environment Conditions
9.1.1 Inspection Conditions:
(1)Inspection Distance: 35 cm±5cm
(2)View Angle : Light-on Inspection Angle︰±5°
Cosmetic Inspection Angle︰±45°
( perpendicular to LCD panel surface)
9.1.2 Environment Conditions:
Ambient Temperature
23℃±5℃
Ambient Humidity 55±10%RH
Cosmetic Inspection more than 600 Lux Ambient
Illumination
Functional Inspection 300~500 Lux
9.1.3 Sampling Conditions:
(1) Lot Size: Quantity of shipment lot per model
(2) Sampling Method:
MIL-STD-105E
Normal Inspection, Single Sampling
Sampling Plan
Level II
Major Defect 1.0%
AQL
Minor Defect 1.5%
(3) The classification of Major(MA) and Minor(MI) defects is shown as 3. Inspection Criteria.
9.1.4 Inspection Criteria
TFT-LCD
45°
Cosmetic Insp.
Light-on Insp.
5°
30cm~40cm
90
°