Datasheet

DEM 320240D TMH-PW-N (A-TOUCH) Production Specification
Version: 1 PAGE: 19
9. Incoming Inspection Standards
9.1 Inspection and Environment Conditions
9.1.1 Inspection Conditions:
(1)Inspection Distance: 35 cm±5cm
(2)View Angle: Light-on Inspection Angle±5°
Cosmetic Inspection Angle±45°
(perpendicular to LCD panel surface)
9.1.2 Environment Conditions:
Ambient Temperature
23±5
Ambient Humidity 55±10%RH
Ambient
Illumination
Cosmetic Inspection more than 600 Lux
Functional Inspection 300~500 Lux
9.1.3 Sampling Conditions:
(1) Lot Size: Quantity of shipment lot per model
(2) Sampling Method:
Sampling Plan
MIL-STD-105E
Normal Inspection, Single Sampling
Level II
AQL
Major Defect 1.0%
Minor Defect 1.5%
(3) The classification of Major (MA) and Minor (MI) defects is shown as 3. Inspection Criteria.
TFT-LCD
45°
Cosmetic Insp.
Light-on Insp.
5°
30cm~40cm
90
°