Datasheet

DEM 320240D TMH-PW-N (A-TOUCH) Production Specification
Version: 1 PAGE: 17
7. Reliability Condition
No change on display and in operation under the following test condition.
Condition: Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20±5°C.
Humidity: 65±5%RH.
Tests will be not conducted under functioning state.
No. Parameter Condition Notes
1 High Temperature Operating 70°C±2°C, 240hrs (Operation state). -
2 Low Temperature Operating -20°C±2°C, 240hrs (Operation state). -
3 High Temperature Storage 80°C±2°C, 240hrs. -
4 Low Temperature Storage -30°C±2°C, 240hrs. -
5
High Temperature and High
Humidity Operation Test
60°C±2°C, 90%, 240hrs. -
6 Vibration Test
Total fixed amplitude: 1.5mm.
Vibration Frequency: 10~55Hz.
One cycle 60 seconds to 3 direction of X, Y, Z each 15
minutes.
-
7. Drop Test
To be measured after dropping from 60cm high on the
concrete surface in packing state.
-
Dropping method corner
dropping:
A corner: Once edge
dropping.
B, C, D edge: Once face
dropping.
E, F, G face: Once.