Datasheet

DEM 20486 SYH-LY Product Specification
Version: 5 PAGE: 1
15. THE MODULE ACCEPT QUALITY LEVEL (AQL)
15.1 AQL Standard Value: Critical Defect =0.1, Major Defect=0.65; Minor Defect =2.5.
15.2 Inspection Standard: MIL-STD-105E Table Normal Inspection Single Sampling Level II
16. RELIABILITY TEST
Operating life time: 50,000 hours (at room temperature without direct irradiation of sunlight)
Reliability characteristics shall meet following requirements.
Test Item Test Condition
High Temperature Storage +80°C x 96hrs
Low Temperature Storage -30°C x 96hrs
High Temperature Operation +70°C x 96hrs
Low Temperature Operation -20°C x 96hrs
High Temperature, High Humidity (Storage) +60°C x 90%RH x 96hrs
Thermal Shock
-20°C x 30min +25°C x 10s +70°C x 30min
5Cycles
Vibration Test
Frequency x Swing x Time
40Hz x 4mm x 4hrs
Drop Test
Drop Height x No. of drops
1.0m x 6 drops