Datasheet
DEM 20485 SYH-LY Product Specification
Version: 3 PAGE: 13
14. MODULE ACCEPT QUALITY LEVEL (AQL).
14.1 AQL Standard Value: Critical Defect =0.1, Major Defect=0.65; Minor Defect =2.5.
14.2 Inspection Plan: MIL-STD-105E, Normal Inspection Level II, Single Sampling Plan
15. RELIABILITY TEST
Operating life time: Longer than 50000 hours (at room temperature without direct irradiation of sunlight)
Reliability characteristics shall meet following requirements.
Temperature Tests Normal Grade
High Temperature Storage +80°C x 96hrs
Low Temperature Storage -30°C x 4hrs
High Temperature Operation +70°C x 96hrs
Low Temperature Operation -20°C x 96hrs
High Temperature, High Humidity +70°C 95%RH 96hrs
Thermal Shock
-20°C x 30 min
10s 5Cycles
+70°C x 30 min
Vibration Test
Frequency x Swing x Time
40Hz x 4mm x 4hrs
Drop Test
Drop Height x Times
1.0m x 6 times