Datasheet

DEM 20231 SYH-PY Product Specification
Version: 4 PAGE: 13
14. MODULE ACCEPT QUALITY LEVEL (AQL).
14.1 AQL Standard Value: Critical Defect =0.1, Major Defect=0.65; Minor Defect =2.5.
14.2 Inspection Standard: ANSI Z-1.4 Table Normal Inspection Single Sampling Level II.
15. RELIABILITY TEST
Operating life time: Longer than 50000 hours (at room temperature without direct irradiation of sunlight)
Reliability characteristics shall meet following requirements.
TEMPERATURE TESTS NORMAL GRADE
High Temperature Storage +75°C x 96hrs
(Without Polarizer)
Low Temperature Storage -25°C x 4hrs
High Temperature Operation +70°C x 96hrs
Low Temperature Operation -20°C x 4hrs
High Temperature, High Humidity
+70°C x 95%RH x 96hrs
(Without Polarizer)
Thermal Shock
-20°C x 30min.
10s 5Cycles
+70°C x 30min.
Vibration Test
Frequency x Swing x Time
40Hz x 4mm x 4hrs
Drop Test
Drop Height x Times
1.0m x 6times