Datasheet

DEM 20231 SYH-PY-CYR22 Product Specification
Version: 2 PAGE: 11
14. MODULE ACCEPT QUALITY LEVEL (AQL).
14.1 AQL Standard Value: Critical Defect =0.1, Major Defect=0.65; Minor Defect =2.5.
14.2 Inspection Standard: ANSI Z-1.4 Table Normal Inspection Single Sampling Level II
15. RELIABILITY TEST
Operating lifetime: Longer than 50000 hours
(at room temperature without direct irradiation of sunlight)
Reliability characteristics shall meet following requirements.
TEMPERATURE TESTS NORMAL GRADE
High temperature storage +75°C x 96hrs
(Without Polarizer)
Low temperature storage -25°C x 4hrs
High temperature operation +70°C x 96hrs
Low temperature operation
-20°C x 4hrs
High temperature, High humidity
+70°C x 95%RH x 96hrs
(Without Polarizer)
Thermal shock
-20°C x 30min.
10s 5Cycles
+70°C x 30min.
Vibration test
Frequency x Swing x Time
40Hz x 4mm x 4hrs
Drop test
Drop height x Times
1.0m x 6times