Datasheet
DEM 16223 SBH-PW-N Product Specification
Version: 4.1.1 PAGE: 14
14. MODULE ACCEPT QUALITY LEVEL (AQL)
14.1 AQL Standard Value: Fatal Defect =0.1, Major Defect=0.65; Minor Defect =2.5.
14.2 Inspection Plan: MIL-STD-105E, Normal Inspection Level II, Single Sampling Plan.
15. RELIABILITY TEST
Operating life time: 50,000 hours (at room temperature without direct irradiation of sunlight)
Reliability characteristics shall meet following requirements.
Test Item Test Condition
High Temperature Storage +75°C x 96hrs
Low Temperature Storage -25°C x 96hrs
High Temperature Operation +70°C x 96hrs
Low Temperature Operation -20°C x 96hrs
High Temperature, High Humidity +60°C x 90%RH x 96hrs
Thermal Shock
-20°C x 30min → +25°C x 10s → +60°C x 30min
5Cycles
Vibration Test
Frequency x Swing x Time
40Hz x 4mm x 4hrs
Drop Test
Drop height x No. of drops
1.0m x 6drops