Datasheet
DEM 16218 SGH Product Specification
VERSION: 2 PAGE: 13
14. THE MODULE ACCEPT QUALITY LEVEL (AQL)
14.1. AQL standard value: Critical defect =0.1, Major defect=0.65; Minor defect =2.5.
14.2. Curtailed Inspection Scheme
Notes: 1). Batch QTY is the product amount that Product department ship to QA department.
2). All of product will be inspected if the batch QTY less than inspected QTY.
3). Each batch standard QTY are 500pcs.
15. RELIABILITY TEST
Operating life time: 50,000 hours (at room temperature without direct irradiation of sunlight)
Reliability characteristics shall meet following requirements.
Tests Item Condition
High temperature storage
+75°C x 96HRS
(Without Polarizer)
Low temperature storage -25°C x 4HRS
High temperature operation +70°C x 96HRS
Low temperature operation -20°C x 4HRS
High temperature, High humidity
+70°C x 95%RH x 96HRS
(Without Polarizer)
Thermal shock
-20°C x 30min à +25°C x 10s à +70°C x 30 min
x 5 cycles
Vibration test
Frequency x Swing x Time
40Hz x 4mm x 4hrs
Drop test
Drop height*Times
1.0m * 6times