Manual
1/17/07
5
Lift Preparation
Unpack Lift – remove phillips head screws & lag screws securing frame & lift to the
pallet. (photo of LCD-100 with Option 4). The lift is shipped upside down. Leave the
wood blocks and plastic tie wraps in place.
Control Box
NOTE:
The factory default setting will not change for most installations.
SET DIP SWITCHES before you install the lift. Be sure there is no power connected to
the lift. The control box is located inside the lift on the upper frame. Depending upon
your lift model the location and orientation of the control box varies.
Dip switches are located under the small access panel on the Control Box attached to
the lift frame. Use a 1/16” Hex driver to open.
ON OFF
SW1 Aux AC Trigger (see SW2 below) Aux AC Trigger is on all the time
SW2 Aux AC Trigger upon going down Aux AC Trigger at show position
SW3 12V out turns off upon going up 12V out turns off at top position
SW4 12V out turns on upon going down 12V out turns on at show position
Dip Switch SW1: configuration only works in automatic mode.
Set the 12 volt trigger and AC Trigger based on your system design.
1 2 3 4
ON
OFF
Default setting