Installation Guide
6
discoverbattery.com
3.4 Connecting LYNK to Power Conversion Electronics
Instructions on networking with specic power electronics are found in the relevant LYNK Edge Card Manual. Refer also to
the specic power electronics guides for system conguration information.
▲ CAUTION
HAZARD OF EQUIPMENT DAMAGE
• Do not plug an AEbus RJ-45 cable terminator into the
10/100 Ethernet port of the LYNK.
• Do not connect a CAT5 cable from the 10/100 Ethernet
port of the LYNK to the WAN or MODEM port of a
network router.
• Turn OFF all devices before connecting cables or
inserting an Edge Card.
Failure to follow these instructions will damage equipment.
▲ NOTE
Power electronics are not AEbus devices and should
not be connected directly to AEbus.
4. Operation
4.1 Turning Power to LYNK ON and OFF
To power up LYNK switch the AES LIFePO
4
battery to ON. To turn off power to LYNK switch the AES LIFePO
4
battery to OFF.
4.3 Power Cycling LYNK
Use a pin to press and briey hold the reset button on the front face of LYNK.
4.4 Firmware Update
Consult the Discover website for the latest rmware. If an rmware update is require, ensure this is done by a qualied installer.
5. Troubleshooting
Symptom
AEbus LED is not on and SOC LEDs are scrolling
Description
Power is detected but there are no AEbus devices communicating
Action
Check that other AEbus Devices are powered on and that the network is properly terminated
M8” bolt (supplied with battery)
Copper compression lug
Shrink-wrap to
color-code the cable
Terminal surface
Lock washer (supplied with battery)
Flat washer (supplied with battery)
Battery cable lug
Ensure nothing is between
the terminal surface and the
battery cable lug