Installation Guide
5
discoverbattery.com
Wall Mount DIN Rail Mount
3.2 LYNK Mounting Options
The Gang Box and Wall Mounts are included. Place the LYNK behind the mount, insert M3 screws through the holes into
threaded inserts on the face of LYNK and secure. Secure all cables to prevent them from becoming damaged. Two threaded
inserts on the back of LYNK can be used to attach a DIN Rail mounting clip. DIN Rail hardware is not included.
3.3 Connecting LYNK to AEbus
▲ CAUTION
HAZARD OF EQUIPMENT DAMAGE
• Do not connect a CAT5 cable from the AEbus network to
the WAN or MODEM port of a network router.
• Turn OFF all devices before connecting cables or
inserting an Edge Card.
• Do not reverse the polarity of the DC power converter.
Failure to follow these instructions can damage equipment.
Using a CAT5 cable insert one end into the AEbus RJ45 port located on the bottom of LYNK. Insert the other end of the CAT5
cable into the AEbus port located on the battery. If there are multiple AES LiFePO4 batteries, series network them together
and insert the end of the CAT5 from LYNK into the AEbus Y-Connector at the end of series network, as shown below.
LYNK requires a 12 volt power source. Connect the y leads of the included DC-DC AEbus power converter to the positive and
negative battery terminals of a AES LiFePO
4
battery. Insert one end of a CAT5 cable into the RJ45 port of the DC-DC AEbus power
converter and then insert the other end into the last AEbus Y-Connector, as shown below.
▲ NOTE
Both LYNK and the DC-DC AEbus
power converter are internally terminated.
Gang Box Mount
Preliminary 20190314