User guide
Using Utilities
20
To print a test label
1 Place a blank printable disc in the input
spindle, label side up.
2 Open the Utilities option and click the Print
Test Label button.
3 The Diagnostics load the printable disc into
the printer and print a test pattern on the
surface.
4 The completed test print disc is unloaded
onto the output spindle.
To run diagnostics
1 Unload any discs from the printer and drives.
2 Click the Run Diagnostics button.
3 Note the status of the numbered indicators
on the duplicator display. Green circles illus
-
trate the functions being tested. A red circle
indicates a failure at the indicated point. You
can also follow the progress of the testing
by reading the log entries on the status line
above the duplicator figure.
4 Once complete, the status line displays either
a failure condition or the message Diagnostic
Complete.
To run diagnostics without the print-
er
1 Open a drive tray and place a disc on the
input spindle.
2 Click the Run Diagnostics button.
3 The Diagnostics pick a disc from the input
spindle, drop it into the open drive, retrieve
the disc from the drive tray, and deposit it on
the output spindle.
4 The status line displays the progress of the
test. Green circles on the duplicator display
show successful tests. Red circles indicate
points of failure.
Note: Depending on the nature of any problems
that are detected during the diagnostics, you may
be able to resolve the issues by consulting the
Troubleshooting FAQ or following the procedures
under other Utility tabs, such as the tab to Set
Positions. In cases where the problem can’t be
eliminated by normal means, contact a technical
support representative at Disc Makers by calling
1-888-800-4041.
To position the Disc Pick arm for
shipping
The disc pick arm should be moved to the safe
(parked) position each time the duplicator is
prepared for shipping or whenever the unit is
physically transported to a different location.
1 Remove all discs from the input and output
spindles.
2 Open the Utilities option.
3 Under the Diagnostics tab, click the button
titled Pack Pick Arm for Shipping.
4 Ensure that the arm moves into the parked
position resting on the plastic bumper.
5 Complete the packing and transport of the
unit.
6 When the unit is again set up and powered
on, the pick arm automatically returns to its
normal operating position.