User guide
User Guide v.1.0 www.discmakers.com/techsupport 28
70
IF ERROR CODE 70 IS SHOWN, IT REPRESENTS THAT A DISC
WAS PICKED FROM AN INPUT BIN AND THE VACUUM PICKING
ARM DROPPED THE DISC ON THE WAY TO ONE OF THE DRIVE
TRAYS.
DISC DROPPED
DURING INPUT
PROCEDURE
71
IF ERROR CODE 71 IS SHOWN, IT REPRESENTS THAT THE
VACUUM PICKING ARM FAILED TO PICK UP A DISC FROM AN
INPUT BIN AFTER 3 CONTINUOUS ATTEMPTS.
FAILURE TO PICK
UP A DISC FROM
INPUT BIN
80
IF ERROR CODE 80 IS SHOWN, IT REPRESENTS THAT A DISC
ATTEMPTING TO BE PLACED ON A DRIVE TRAY REMAINED
ATTACHED TO THE VACUUM BLOCK AND WAS NOT PROPERLY
DROPPED FROM THE VACUUM PICKING ARM INTO THE DRIVE
TRAY.
DISC REMAING ON
VACUUM BLOCK
NOT LOADED ON
TO THE DRIVE
TRAY
90
IF ERROR CODE 90 IS SHOWN, IT REPRESENTS THAT A DISC
WAS PICKED FROM A DRIVE TRAY AND THE VACUUM PICKING
ARM DROPPED THE DISC ON THE WAY TO THE APPROPRIATE
OUTPUT BIN.
DISC DROPPED
DURING OUTPUT
PROCEDURE
A0
IF ERROR CODE A0 IS SHOWN, IT REPRESENTS THAT THE
OUTPUT BIN IS FULL. THIS COMMONLY OCCURS IF THE INPUT
BIN WAS FILLED WITH MORE DISCS WHILE COMPLETED DISCS
WERE DEPOSITED TO THE OUTPUT BINS INCREASING THE
TOTAL DISC CAPACITY BEYOND THE MAXIMUM OUTPUT
CAPACITY.
OUTPUT BIN FULL
B0
IF ERROR CODE B0 IS SHOWN, IT REPRESENTS THAT THE
VACUUM PICKING ARM IS ATTEMPTING TO REMOVE A DISC
FROM A DRIVE TRAY AND CANNOT DETECT THE DISC. THIS
COMMONLY OCCURS WHEN THE DISC WAS REMOVED FROM
THE TRAY BEFORE THE VACUUM PICKING ARM HAD AN
OPPORTUNITY TO PICK IT UP.
CANNOT DETECT
DISC IN DRIVE
TRAY
C0 ~
C5
IF ERROR CODE C0 ~ C5 IS SHOWN, IT REPRESENTS THAT A
DISC BEING RETURNED TO THE OUTPUT/NG WAS NOT
PROPERLY DROPPED FROM THE VACUUM PICKING ARM ONTO
THE OUTPUT BIN 0 ~ 5, RESPECTIVELY, WHERE BIN 0
INDICATES THE POSITION RIGHT IN FRONT OF THE DRIVE
HOUSING.
DISC MISLOADED
IN OUTPUT BIN #
FF
TOO MUCH STATIC ELECTRICITY BUILD UP FROM THE DISC.
THIS ERROR OCCURS WHEN THE STATIC ELECTRICITY ON THE
DISC IS TOO HIGH. EITHER THE FACILITY PRODUCES TOO
MUCH STATIC ELECTRICITY OR THE CURRENT CLIMATE IS
CONDUCIVE TO HIGH CONCENTRATION OF STATIC
ELECTRICITY. THIS ERROR IS CAUSED BY THE BUILD UP OF AN
ELECTRIC STATIC CHARGE WHICH SHOCKS THE ROBOTIC ARM
WHILE LOADING A DISC. IF THIS ERROR SHOULD OCCUR, THE
USER MUST COMPLETELY REBOOT THE SYSTEM BY TURNING
THE UNIT OFF AT THE POWER BUTTON. WHEN THE UNIT IS
TURNED ON AGAIN, IT SHOULD OPERATE NORMALLY, BUT YOU
WILL NEED TO REPROGRAM THE JOB IT WAS RUNNING.
HIGH STATIC
SHOCK ERROR