Technical data

11
Central vacuum systems
it is necessary that both the resistances and the
electronic control device are mounted.
Code IS02 device for models with 2 motors
(Mod. DS B02 and DS D02)
Code IS03 device for models with 3 motors
(Mod. DS C03 and DS F03)
Suggestions for extended systems
With the models DSA01 and DSB01 mount the
resistances on the inlet valves and the electronic
control device only when it is planned to extend the
system.
With the models DSB02 and DSD02 we suggest to
install at once the device for 3 motors.
Use of the system with sequential starting
device
This kind of system allows the sequential starting
device of motors requested. It comes a real energy
saving.
For the functioning of the sequential starting system,
install inlet valves equipped with resistances (IS106)
to be welded on the electrical cable at the output
of the inlet valve. The connection of the line is
always in parallel.
If the resistance is ordered with the inlet valve
please add “R” at the end of the code of the valve.
Ex: SD310R. For the functioning of the sequential
starting device system you need the special
electronic control. For the functioning of the system
3
2
6
4
1
8
Description:
1 electric contact
2 tubing
3 electric control line
4 terminal inside the backup box
5 resistance
6 electric division box for 12V remote control wire
7 electric junction box
8 central vacuum cleaner
5
7
ZONE 2
ZONES 4 and 5
ZONE 3
ZONE 1
Systems with more than 30 inlet valves
Z 854