Technical data

37
6 Before every use
GB
6 Before every use
6.1 Adjusting the sensitivity of the fall sensors
1. Ensure that the appliance is switched off
(On/Off switch in the "0" position).
2. Adjust the setting of the slide controller to
the sensitivity setting of the 3 fall sensors
(Fig. 18):
- Position 0 for light floors and low steps
- Position 1 for light floors and slightly
higher steps
- Position 2 for dark floors and even high-
er steps
- Position 3 for dark floors and high steps
1
16
3 2 1 0
3 2 1 0
17
3 2 1 0
3 2 1 0
18
WARNING:
Danger of injury! Ensure that the appliance
is switched off (On/Off switch in the "0"
position), before you mount the round
brooms.
All 3 slide controllers must have the same
setting.
NOTE:
If your robot moves backward continuously
on dark floors, you must select the "1" set-
ting (Fig. 18).
Libero.book Seite 37 Montag, 12. März 2012 6:29 18