CHAPTER 4: Operation
Clocking
The device offers several options for clocking.
PTP (Precision Time Protocol) - IEEE1588-2008 / PTPv2
Word Clock
Video Reference - NTSC/PAL (black burst)
MADI input
internal clock generator (not PTP)
When PTP (network) is selected the device can either act as slave or as network
grandmaster. There is also a mechanism provided that allows to auto-negotiate the
PTP master/slave state between connected devices.
WCK
OUT / IN
2 x BNC socket (coaxial), 75 Ω
OUT: word clock output, connect here for word clock
output signal (AES11)
IN: word clock input, connect word clock signal
(AES11) here.
VIDEO SYNC 1 x BNC socket (coaxial), 75 Ω
Video reference input, connect video reference signal
(black burst) here.
NOTE
If MONTONE.42 is synchronised to a different clock source than PTP it shall be
Grandmaster in order to provide synchronised streams. See also “PTP Settings”
on page 37.