CHAPTER 4: Operation
Amplitude
If the BNC input is selected, the voltage of the MADI carrier is measured. Using
the SFP input the module’s DDM* signalling is utilized. The analysis results are
indicated by ‘traffi c light’ leds.
Code BNC SFP LED Code
-- no SFP with
DDM
< 150 mV low power alarm LEFT FLASHING, red
MID OFF
RIGHT OFF
< 300 mV low power
warning
LEFT ON, yellow
MID OFF
RIGHT OFF
< 600 mV ok
(if SFP with
DDM)
LEFT OFF
MID ON, green
RIGHT OFF
< 800 mV high power
warning
LEFT OFF
MID OFF
RIGHT ON, yellow
> 800 mV high power alarm LEFT OFF
MID OFF
RIGHT FLASHING, red
* appropriate SFP Modules: see „Accessory“ on page 13.
NOTE!
The AES10 spec requires the voltage of the carrier to be between 300..600 mV.
NOTE
It is advised to perform the calibration of the BNC I/O at periodic intervals - see
page 33.