Manual

page 29 of 40MADI.MONI Manual - Version 1.1
CHAPTER 4: Operation
Frame Format
The frame format of the selected input is indicated by two leds. 96k Frame is
available at 2 FS only while 48k Frame may be used at 1 FS, 2 FS and 4 FS. Thus a
48k Frame MADI signal needs the scaling factor to be adjusted manually for proper
monitoring - see „Display - Menu settings“ on page 24.
Code Meaning LED Code
48k Frame 48k ON, green
96k OFF
96k Frame 48k OFF
96k ON, yellow
NOTE!
A 96k Frame signal forces the scaling factor temporarily to 2FS. Once a 48k Frame
signal is detected the set scaling factor is resumed.