CHAPTER 4: Operation
Operating Principles
The device is operated via four push buttons, ‘VOL/CH’ and ‘MENU’ navigate the
parameters. The two ‘SET’ buttons (▲▼) are used for adjusting parameter values.
‘Signal Format’ and ‘Signal Quality’ inform about the signal state of the selected
input. The values of ‘Signal Quality’ are expressed by using different colors and
combinations of the three LEDs (‘traffi c light’).
The alphanumeric display monitors the signal level of the selected channel(s) for
monitoring. Using the navigation buttons it can be toggled to temporary display of
volume level or the selected channel for monitoring or the individual parameters of
the device settings.
On the following pages each parameter and its corresponding values are
described. The „Menu Structure“ on page 27 provides a basic overview of the
device settings.
Inputs
Signal Format
Signal Quality
Navigation Adjust
Parameter
Volume Level
Channel Selection
Device Setting
Level Meter