page 87 of 93EXBOX.RAV Manual - Version 1.1
Appendix C - Working with ch 57 mode
Appendix C - Working with ch 57 mode
Channel mode 57 ch on the MADI output enables transparent pass-through of
embedded control data that is used by DiGiCo consoles.
Ch 57 mode is detected at the MADI input automatically and signaled to the user.
To preserve the control data throughout the signal chain:
• set MADI output to 57 ch mode
• route input channel 57 to output channel 57
The control data is preserved also across a RAVENNA connection to another
EXBOX.RAV, where it is output to MADI.
NOTE
The incoming control data is neither examined nor altered by the device.